Installation of fuel tank and selection of cutting oil type:
Installation: The equipment fuel tank has multiple layers of filters, which are placed and installed according to the above diagram without the need for screws to fix them, making it easy to clean residue After the installation of the filter screen, check whether the drainage outlet is sealed and locked with raw material to avoid leakage after refueling.
Oil type selection: It is recommended to use cutting fluid (coolant), which is an industrial liquid used in metal cutting and grinding processes to cool and lubricate cutting tools and workpieces. Cutting fluid is composed of a variety of super functional additives scientifically compounded, and has good cooling performance, lubrication performance, rust prevention performance, oil removal and cleaning function, anti-corrosion function, and easy dilution characteristics. The cooling effect of cutting fluid is to remove the heat generated by cutting from the tool and workpiece through convection and vaporization between it and the tool, chips, and workpiece, thereby effectively reducing the cutting temperature, minimizing thermal deformation of the workpiece and tool, maintaining tool hardness, improving machining accuracy and tool durability.
Special warning: Do not use tap water, otherwise it may cause rusting of equipment components/tools, uneven processing of products, as water is a conductor and can also cause short circuits and burnout of equipment spindles and electronic components Remember, remember!!
Horizontal adjustment of equipment and machinery:
Please check the horizontal position of the equipment before production. If the equipment is not installed horizontally, it will affect the accuracy of the processed product and the service life of the equipment's screw guide rail May cause issues such as abnormal motor noise.
Horizontal adjustment method: It is recommended to use a high-precision bar level. The bar level is a universal angle measuring instrument that uses the principles of liquid flow and liquid level to directly display angular displacement with a level bubble and measure small oblique angles relative to the horizontal position.
1.Before measurement, the measuring surface should be carefully cleaned and wiped dry to check for defects such as scratches, rust, and burrs.
2.Before measurement, check if the zero position is correct.
3.When measuring, the influence of temperature should be avoided. The liquid inside the level has a significant impact on temperature changes. Therefore, attention should be paid to the effects of hand heat, direct sunlight, and humidity on the level.
4.Horizontal adjustment method:
Place the floor mats provided with this device on the four feet of the equipment, and place the bar level on the clean surface of the equipment workbench. Use a sheet metal wrench to adjust the screws on the bottom four feet of the equipment, paying attention to adjusting the vertical and horizontal directions of the equipment (front and back horizontal and left and right horizontal). During the adjustment process, observe the level of the level and adjust the level bubble to be located in the middle of the level The following figure:
5.Air pressure alarm
The rated air pressure of the equipment is 0.6 Pa and cannot be lower than 0.5 Pa. If it is lower than 0.5 Pa, the equipment will issue a low air pressure alarm The processing program will stop urgently and can only be manually controlled to continue running after the air pressure is restored Insufficient air pressure can affect the signal of the loose clamping tool on the spindle, causing an abnormal alarm and preventing the equipment from operating normally To confirm if the air pressure is sufficient, you can open the pneumatic cabinet behind the equipment to check the pressure gauge, as shown in the following figure.